Flux-Off CZ

Non-ozone depleting, nonflammable flux remover spray safe for use on plastics.

Flux-Off® CZ Flux Remover is a highly effective cleaner for removing rosin-based fluxes from electronic components and assemblies. Utilizing Cirozane™, which is based on new HFE technology, this nonflammable, non-ozone depleting aerosol quickly removes flux without harming sensitive materials.

CIROZANE™ Cleaning Chemistry (CZ) - Now, with CIROZANE CFC / HCFC Replacement chemistry, you won’t need to make any more undesirable trade-offs. CIROZANE-based products offer you a high performance, ultra-safe “drop-in” replacement to all CFC and HCFC chemistries.

CIROZANE chemistry is the result of an 18-month research effort. CIROZANE-based products offer all the performance of CFCs and HCFCs without any ozone depleting compounds.

Available with The BrushClean™ System - Gentle scrubbing action of a brush combined with high performance flux remover. Click here for more information.

CLICK HERE FOR FLUX REMOVER SELECTION GUIDE

Features & Benefits

  • Safe on plastics
  • Nonflammable
  • Cleans R, RMA, RA, and no-clean flux
  • Dries fast
  • Leaves no residue
  • All-Way Spray valve - even sprays upside down
  • Available with BrushClean™ System

Applications

  • The best “no worry” flux remover
  • Ideal for replacing ozone depleting chemistries
Shelf Life 5 yrs.
Shipping Name Consumer Commodity ORM-D
Harmonization Code 3814
Specifications Unison Ind. 74-11-12-940-801-A
Used to clean components
Call-outs Boeing - 74-11-01-200-801-F00
Boeing - 74-11-01-210-006-F00
Boeing - 74-21-02-400-801-F00
Boeing - 74-21-02-210-007-F00
NSN ES7200 - 6850-01-436-4578
ES7201 - 6850-01-436-4579

Swipe to View Add to Cart Button 

Part # Size Units Per Case
ES7208B

5 oz / 141 g BrushClean™ System

12 cans
ES7200

12 oz / 340 g aerosol

12 cans
Order from an authorized distributor

FAQ's

How can you reduce chemical exposure?

Every organization using hazardous chemicals within their facility has the responsibility to equip their facility and personnel to maintain exposure levels below the TLV. Personal monitoring badges can be used to measure exposure of a specific material. Then, depending on the threshold limit and the application, exposure can be controlled with PPE like masks, face shields, respirators, and even coveralls. If they don’t reduce exposure below the recommended limit, you will need to consider a special ventilation hood or even containment booth. As you can see, as the exposure limit gets down to a certain level, the equipment required to safely use the solvent can get impractical. At that point, your best option is to consider a safer alternative.

How do you know the safe exposure limit of a degreaser, contact cleaner, or flux remover?

The personal hazard associated with a solvent is often defined using Threshold Limit Value (TLV), which is the recommended average exposure in an 8-hour day, 40 hour work week. The lower the TLV of a particular substance, the less a worker can be exposed to without harmful effects. TLV is stated on the SDS of chemical products, in additional to recommended personal protection equipment (or PPE). The threshold limit value of a solvent is generally set by the American Conference of Governmental Industrial Hygienists (ACGIH). The unit of measure is Parts Per Million (PPM). 

How do you use an aerosol cleaner?

Hold object to be cleaned in vertical position. Pull trigger gently to control solvent flow rate. Scrub with brush from top to bottom, allowing the liquid to flush away contaminants. 

How do I properly dispose of an aerosol can after it is empty?

It may be different state-by-state, so contact your state environmental agency for regional specific regulations. For a general guideline, here is the process according to EPA hazardous waste regulations 40CFR. The can has to be brought to or approach atmospheric pressure to render the can empty. Puncturing is not required, only that it “approach atmospheric pressure”, i.e. empty the can contents until it’s no longer pressurized. This insures that as much contents as is reasonably possible are out of the can. It is then considered “RCRA-empty”. At that point it can be handled as any other waste metal container, generally as scrap metal under the recycling rules. Note that the can is still considered a solid waste at this point (not necessarily hazardous waste).

Is there something I can do with the extension tube (straw) so it doesn’t get lost?

The red cap on Chemtronics aerosol products like flux removers, degreasers, and Freeze-It Freeze Spray has a notch on the top. That is engineered for the straw to snap in and hold into place so you don’t loose it. The aerosol trigger sprayers that are common on dusters, freeze sprays, and flux removers, have two ways to store the straw when not in use. The hole at the back of the body of the sprayer is just the right size for the straw to slide into place for storage. The slot below the trigger is also the right size for the straw to snap into place, which also has the advantage of locking the trigger.

How do I figure out the shelf life of a product?

The shelf life of a product can be found on either the technical data sheet (TDS), available on the product page, or by looking on the certificate on conformance (COC). The COC can be downloaded by going to https://www.chemtronics.com/coc. Once you have the shelf life, you will need to add it to the manufacture date for a use-by date. The manufacture date can be identified by the batch number. The batch code used on most of our products are manufacture dates in the Julian Date format. The format is YYDDD, where YY = year, DDD = day. For example, 19200 translates to the 200th day of 2019, or July 19, 2019. This webpage explains and provides charts to help interpret our batch numbers: https://www.chemtronics.com/batch-codes.

Articles

There are a number of regulations prohibiting the use of chlorinated solvents. Should I be concerned with Trans, which is used in many of your nonflammable cleaners?

There are a number of regulations prohibiting the use of chlorinated solvents. Should I be concerned with Trans, which is used in many of your nonflammable cleaners?

No, it should not be a concern. Many of Chemtronics' nonflammable solvents (e.g. Electro-Wash VZ, Flux-Off Tri-V) contain 1,2-trans-dichloroethylene (Trans, CAS# 156-60-5), which has caused confusion. The regulations controlling chlorinated solvents do not generally pertain to Trans. The following a...
Read This Post
Flux Remover Video User's Guide

Flux Remover Video User's Guide

Today, I’m going to take you through the best practices for cleaning printed circuit boards with a flux remover. A flux remover cleans off flux left behind after the soldering process. That’s important because flux residue can cause corrosion or create what’s called “dendrites”, which are ionic par...
Read This Post
Ultimate Guide to Cleaning Electronics: Improve PCB Reliability Safely & Effectively

Ultimate Guide to Cleaning Electronics: Improve PCB Reliability Safely & Effectively

In the process of assembling, reworking or repairing printed circuit boards (PCB) for electronic devices, the discussion inevitably turns to whether or not to clean the PCB. Cleaning adds time and expense to the process, and doing it wrong can cause more harm than good. This guide will walk you thro...