Conformal Coating Selection Guide

Click on product name for details.

Key: 1 – Outstanding    2 – Excellent    3 – Good    4 – Fair    NA – Not Available

Konform SR Konform SR HV Konform AR Konform LED
Resistance
Temperature Resistance 1 1 2 1
Abrasion Resistance 4 4 1 4
Acid Resistance 2 2 1 2
Solvent Resistance 2 2 3 2
Humidity Resistance 1 1 1 1
Underwriters Laboratories
Water Submersible Per UL X X
UL Recognized X X
UV Traceable X X X
Coating Characteristics
Flexibility 1 1 4 1
Solderability 4 4 3 4
Repairability 3 3 4 3
Dielectric Breakdown 1100 1100 8300 1100
Working Temperature -85F to 390º (-65ºC to 200º) -85F to 390º (-65ºC to 200º) -75F to 270º (-59ºC to 132º) -85F to 390º (-65ºC to 200º)
Cure Profile
Tack Free Time 15 min 15 min 30 min 15 min
Full Cure Time 24 hrs @RT 24 hrs @RT 24 hrs @RT 24 hrs @RT

Click on product name for details.

Key: 1 – Outstanding    2 – Excellent    3 – Good    4 – Fair    NA – Not Available

Konform Ultra Konform UR-A Konform HR
Resistance
Temperature Resistance 2 3 3
Abrasion Resistance 2 1 1
Acid Resistance 1 1 1
Solvent Resistance 3 1 2
Humidity Resistance 1 4 4
Underwriters Laboratories
Water Submersible Per UL
UL Recognized
UV Traceable X X X
Coating Characteristics
Flexibility 4 3 4
Solderability 3 3 3
Repairability 3 4 4
Dielectric Breakdown 8300 3340 7100
Working Temperature -75F to 270º (-59ºC to 132º) -85F to 257º (-65ºC to 125º) -31F to 212º (-35ºC to 100º)
Cure Profile
Tack Free Time 10 min 1 hr 1 hr
Full Cure Time 24 hrs @RT 24 hrs @RT 24 hrs @RT